Matter Survey

Community-basierte Datenbank für Matter-Gerätefunktionen

Pump Configuration and Control 0x0200

Matter 1.4
ClusterRevision 4
An interface for configuring and controlling pumps.

Attributes (23)

Code Name Type
0x0000 MaxPressure int16s
0x0001 MaxSpeed int16u
0x0002 MaxFlow int16u
0x0003 MinConstPressure int16s
0x0004 MaxConstPressure int16s
0x0005 MinCompPressure int16s
0x0006 MaxCompPressure int16s
0x0007 MinConstSpeed int16u
0x0008 MaxConstSpeed int16u
0x0009 MinConstFlow int16u
0x000A MaxConstFlow int16u
0x000B MinConstTemp int16s
0x000C MaxConstTemp int16s
0x0010 PumpStatus PumpStatusBitmap
0x0011 EffectiveOperationMode OperationModeEnum
0x0012 EffectiveControlMode ControlModeEnum
0x0013 Capacity int16s
0x0014 Speed int16u
0x0015 LifetimeRunningHours int24u
0x0016 Power int24u
0x0017 LifetimeEnergyConsumed int32u
0x0020 OperationMode OperationModeEnum
0x0021 ControlMode ControlModeEnum

Features (7)

Bit Code Name
0 PRSCONST ConstantPressure — Supports operating in constant pressure mode
1 PRSCOMP CompensatedPressure — Supports operating in compensated pressure mode
2 FLW ConstantFlow — Supports operating in constant flow mode
3 SPD ConstantSpeed — Supports operating in constant speed mode
4 TEMP ConstantTemperature — Supports operating in constant temperature mode
5 AUTO Automatic — Supports operating in automatic mode
6 LOCAL LocalOperation — Supports operating using local settings