The Electrical Energy Measurement cluster (0x0091) is a Matter cluster that Provides a mechanism for querying data about electrical energy imported or provided by the server, enabling energy monitoring and reporting.. It defines 6 attributes and is mandatory for 1 device type.
Electrical Energy Measurement 0x0091
Provides a mechanism for querying data about electrical energy imported or provided by the server, enabling energy monitoring and reporting.
Spec History
This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.
Attributes 6
Features 6
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | Accuracy | MeasurementAccuracyStruct | |
| 0x0001 |
CumulativeEnergyImported
nullable
|
EnergyMeasurementStruct | Optional |
| 0x0002 |
CumulativeEnergyExported
nullable
|
EnergyMeasurementStruct | Optional |
| 0x0003 |
PeriodicEnergyImported
nullable
|
EnergyMeasurementStruct | Optional |
| 0x0004 |
PeriodicEnergyExported
nullable
|
EnergyMeasurementStruct | Optional |
| 0x0005 |
CumulativeEnergyReset
nullable
|
CumulativeEnergyResetStruct | Optional |
ImportedEnergy
(IMPE)
bit 0
Measurement of energy imported by the server
ExportedEnergy
(EXPE)
bit 1
Measurement of energy provided by the server
CumulativeEnergy
(CUME)
bit 2
Measurements are cumulative
PeriodicEnergy
(PERE)
bit 3
Measurements are periodic
ApparentEnergy
(APPE)
bit 4
Measurements report apparent energy
ReactiveEnergy
(REAE)
bit 5
Measurements report reactive energy
Device Types Using This Cluster
Device types in the Matter spec that reference this cluster
Devices Implementing This Cluster
52 devices in the survey implement this cluster