The Electrical Power Measurement cluster (0x0090) is a Matter cluster that Provides a mechanism for querying data about electrical power as measured by the server, including voltage, current, and power readings for both AC and DC systems.. It defines 19 attributes and is mandatory for 1 device type.

Electrical Power Measurement 0x0090

Application Cluster
Measurement
Introduced in: Matter 1.3
Devices: 52
Provides a mechanism for querying data about electrical power as measured by the server, including voltage, current, and power readings for both AC and DC systems.

Spec History

This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.

Attributes 19
Features 5
Code Name Type Flags
0x0000 PowerMode
0x00..0x02
PowerModeEnum
0x0001 NumberOfMeasurementTypes
min 1
int8u
0x0002 Accuracy array
0x0003 Ranges array Optional
0x0004 Voltage
-4611686018427387904..4611686018427387904 · nullable
voltage_mv Optional
0x0005 ActiveCurrent
-4611686018427387904..4611686018427387904 · nullable
amperage_ma Optional
0x0006 ReactiveCurrent
-4611686018427387904..4611686018427387904 · nullable
amperage_ma Optional
0x0007 ApparentCurrent
-4611686018427387904..4611686018427387904 · nullable
amperage_ma Optional
0x0008 ActivePower
-4611686018427387904..4611686018427387904 · nullable
power_mw
0x0009 ReactivePower
-4611686018427387904..4611686018427387904 · nullable
power_mvar Optional
0x000A ApparentPower
-4611686018427387904..4611686018427387904 · nullable
power_mva Optional
0x000B RMSVoltage
-4611686018427387904..4611686018427387904 · nullable
voltage_mv Optional
0x000C RMSCurrent
-4611686018427387904..4611686018427387904 · nullable
amperage_ma Optional
0x000D RMSPower
-4611686018427387904..4611686018427387904 · nullable
power_mw Optional
0x000E Frequency
0..1000000 · nullable
int64s Optional
0x000F HarmonicCurrents
nullable
array Optional
0x0010 HarmonicPhases
nullable
array Optional
0x0011 PowerFactor
-10000..10000 · nullable
int64s Optional
0x0012 NeutralCurrent
-4611686018427387904..4611686018427387904 · nullable
amperage_ma Optional
DirectCurrent (DIRC) bit 0
Supports measurement of direct current
AlternatingCurrent (ALTC) bit 1
Supports measurement of alternating current
PolyphasePower (POLY) bit 2
Supports polyphase measurements
Harmonics (HARM) bit 3
Supports measurement of AC harmonics
PowerQuality (PWRQ) bit 4
Supports measurement of AC harmonic phases

Device Types Using This Cluster

Device types in the Matter spec that reference this cluster

Devices Implementing This Cluster

52 devices in the survey implement this cluster