The On/Off cluster (0x0006) is a Matter cluster that Controls the on/off state of a device. The most fundamental control cluster used by lights, switches, plugs, and many other devices.. It defines 6 commands and 5 attributes and is mandatory for 29 device types.
On/Off 0x0006
Controls the on/off state of a device. The most fundamental control cluster used by lights, switches, plugs, and many other devices.
Spec History
This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.
Attributes 5
Commands 6
Features 3
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | OnOff | boolean | |
| 0x4000 | GlobalSceneControl | boolean | Optional |
| 0x4001 | OnTime | int16u | Writable Optional |
| 0x4002 | OffWaitTime | int16u | Writable Optional |
| 0x4003 |
StartUpOnOff
max 2 · nullable
|
StartUpOnOffEnum | Writable Optional write: manage |
| Code | Name | Direction | Parameters |
|---|---|---|---|
| 0x00 |
Off
On receipt of this command, a device SHALL enter its ‘Off’ state. This state is device dependent, but it is recommended that it is used for power off or similar functions. On receipt of the Off command, the OnTime attribute SHALL be set to 0.
|
client→server | None |
| 0x01 |
On
Optional On receipt of this command, a device SHALL enter its ‘On’ state. This state is device dependent, but it is recommended that it is used for power on or similar functions. On receipt of the On command, if the value of the OnTime attribute is equal to 0, the device SHALL set the OffWaitTime attribute to 0.
|
client→server | None |
| 0x02 |
Toggle
Optional On receipt of this command, if a device is in its ‘Off’ state it SHALL enter its ‘On’ state. Otherwise, if it is in its ‘On’ state it SHALL enter its ‘Off’ state. On receipt of the Toggle command, if the value of the OnOff attribute is equal to FALSE and if the value of the OnTime attribute is equal to 0, the device SHALL set the OffWaitTime attribute to 0. If the value of the OnOff attribute is equal to TRUE, the OnTime attribute SHALL be set to 0.
|
client→server | None |
| 0x40 |
OffWithEffect
Optional The OffWithEffect command allows devices to be turned off using enhanced ways of fading.
|
client→server |
EffectIdentifier: EffectIdentifierEnum, EffectVariant: enum8 |
| 0x41 |
OnWithRecallGlobalScene
Optional This command allows the recall of the settings when the device was turned off.
|
client→server | None |
| 0x42 |
OnWithTimedOff
Optional This command allows devices to be turned on for a specific duration with a guarded off duration so that SHOULD the device be subsequently turned off, further OnWithTimedOff commands, received during this time, are prevented from turning the devices back on.
|
client→server |
OnOffControl: OnOffControlBitmap, OnTime: int16u, OffWaitTime: int16u |
Lighting
(LT)
bit 0
Behavior that supports lighting applications.
DeadFrontBehavior
(DF)
bit 1
Device has Dead Front behavior
OffOnly
(OFFONLY)
bit 2
Device supports the OffOnly Feature feature
Device Types Using This Cluster
Device types in the Matter spec that reference this cluster
📱
📺
📱
📺
📱
💡
🌉
📱
📱
💡
🔌
📱
📱
📱
💨
🌡
📱
📱
📱
🔘
💡
🔘
🔌
🔘
📱
📱
📱
🔊
📱
Air Purifier
Optional Server
Basic Video Player
Mandatory Server
Casting Video Client
Mandatory Client
Casting Video Player
Mandatory Server
Color Dimmer Switch
Mandatory Client
Color Temperature Light
Mandatory Server
Control Bridge
Mandatory Client
Cook Surface
Optional Server
Cooktop
Mandatory Server
Dimmable Light
Mandatory Server
Dimmable Plug-In Unit
Mandatory Server
Dimmer Switch
Mandatory Client
Dishwasher
Optional Server
Extended Color Light
Mandatory Server
Fan
Optional Server
Heating/Cooling Unit
Mandatory Server
Laundry Dryer
Optional Server
Laundry Washer
Optional Server
Mounted Dimmable Load Control
Mandatory Server
Mounted On/Off Control
Mandatory Server
On/Off Light
Mandatory Server
On/Off Light Switch
Mandatory Client
On/Off Plug-in Unit
Mandatory Server
On/Off Sensor
Mandatory Client
Pump
Mandatory Server
Pump Controller
Mandatory Client
Room Air Conditioner
Mandatory Server
Speaker
Mandatory Server
Video Remote Control
Mandatory Client
Devices Implementing This Cluster
377 devices in the survey implement this cluster
Tapo Smart Wi-Fi Light Switch
Tapo
LIFX Downlight
Feit Electric
NSPanel Pro
SONOFF
Cync Paddle Dimmer
GE Lighting, a Savant company
Xeenos Go Aktor Switch 2K UP
WAREMA Renkhoff SE
Govee Neon Light
Shenzhen Qianyan Technology
Govee Floor Lamp 3
Shenzhen Qianyan Technology
Zemismart M1 Hub
Zemismart Technology Limited
Smartlightbulb
Espressif Systems
Smart Plug
Hama GmbH
Philips G95 Filament
Signify
Aqara Light Switch H2
Aqara
ANTELA Smart Plug
Hangzhou Mango Network Technology Co, LTD.
InvisOutlet
Intecular
Govee Pendant Light
Shenzhen Qianyan Technology
WiZ Downlight
Signify
Smart Home Hub
SONOFF
Sengled Wi-Fi Plug
Sengled
SMART MATDECORWALLTWIST230X127TW
LEDVANCE
Square D Wifi Receptacle
Schneider Electric
not-specified
小鱼科技(玉林市玉州区)责任有限公司
Smart RGBTW Bulb
Leedarson
Decora Smart Wi-Fi Motion Sensing Dimmer
Leviton
Smart RGBTW Bulb
Leedarson