The On/Off cluster (0x0006) is a Matter cluster that Controls the on/off state of a device. The most fundamental control cluster used by lights, switches, plugs, and many other devices.. It defines 6 commands and 5 attributes and is mandatory for 29 device types.
On/Off 0x0006
Controls the on/off state of a device. The most fundamental control cluster used by lights, switches, plugs, and many other devices.
Spec History
This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.
Attributes 5
Commands 6
Features 3
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | OnOff | boolean | |
| 0x4000 | GlobalSceneControl | boolean | Optional |
| 0x4001 | OnTime | int16u | Writable Optional |
| 0x4002 | OffWaitTime | int16u | Writable Optional |
| 0x4003 |
StartUpOnOff
max 2 · nullable
|
StartUpOnOffEnum | Writable Optional write: manage |
| Code | Name | Direction | Parameters |
|---|---|---|---|
| 0x00 |
Off
On receipt of this command, a device SHALL enter its ‘Off’ state. This state is device dependent, but it is recommended that it is used for power off or similar functions. On receipt of the Off command, the OnTime attribute SHALL be set to 0.
|
client→server | None |
| 0x01 |
On
Optional On receipt of this command, a device SHALL enter its ‘On’ state. This state is device dependent, but it is recommended that it is used for power on or similar functions. On receipt of the On command, if the value of the OnTime attribute is equal to 0, the device SHALL set the OffWaitTime attribute to 0.
|
client→server | None |
| 0x02 |
Toggle
Optional On receipt of this command, if a device is in its ‘Off’ state it SHALL enter its ‘On’ state. Otherwise, if it is in its ‘On’ state it SHALL enter its ‘Off’ state. On receipt of the Toggle command, if the value of the OnOff attribute is equal to FALSE and if the value of the OnTime attribute is equal to 0, the device SHALL set the OffWaitTime attribute to 0. If the value of the OnOff attribute is equal to TRUE, the OnTime attribute SHALL be set to 0.
|
client→server | None |
| 0x40 |
OffWithEffect
Optional The OffWithEffect command allows devices to be turned off using enhanced ways of fading.
|
client→server |
EffectIdentifier: EffectIdentifierEnum, EffectVariant: enum8 |
| 0x41 |
OnWithRecallGlobalScene
Optional This command allows the recall of the settings when the device was turned off.
|
client→server | None |
| 0x42 |
OnWithTimedOff
Optional This command allows devices to be turned on for a specific duration with a guarded off duration so that SHOULD the device be subsequently turned off, further OnWithTimedOff commands, received during this time, are prevented from turning the devices back on.
|
client→server |
OnOffControl: OnOffControlBitmap, OnTime: int16u, OffWaitTime: int16u |
Lighting
(LT)
bit 0
Behavior that supports lighting applications.
DeadFrontBehavior
(DF)
bit 1
Device has Dead Front behavior
OffOnly
(OFFONLY)
bit 2
Device supports the OffOnly Feature feature
Device Types Using This Cluster
Device types in the Matter spec that reference this cluster
📱
📺
📱
📺
📱
💡
🌉
📱
📱
💡
🔌
📱
📱
📱
💨
🌡
📱
📱
📱
🔘
💡
🔘
🔌
🔘
📱
📱
📱
🔊
📱
Air Purifier
Optional Server
Basic Video Player
Mandatory Server
Casting Video Client
Mandatory Client
Casting Video Player
Mandatory Server
Color Dimmer Switch
Mandatory Client
Color Temperature Light
Mandatory Server
Control Bridge
Mandatory Client
Cook Surface
Optional Server
Cooktop
Mandatory Server
Dimmable Light
Mandatory Server
Dimmable Plug-In Unit
Mandatory Server
Dimmer Switch
Mandatory Client
Dishwasher
Optional Server
Extended Color Light
Mandatory Server
Fan
Optional Server
Heating/Cooling Unit
Mandatory Server
Laundry Dryer
Optional Server
Laundry Washer
Optional Server
Mounted Dimmable Load Control
Mandatory Server
Mounted On/Off Control
Mandatory Server
On/Off Light
Mandatory Server
On/Off Light Switch
Mandatory Client
On/Off Plug-in Unit
Mandatory Server
On/Off Sensor
Mandatory Client
Pump
Mandatory Server
Pump Controller
Mandatory Client
Room Air Conditioner
Mandatory Server
Speaker
Mandatory Server
Video Remote Control
Mandatory Client
Devices Implementing This Cluster
377 devices in the survey implement this cluster
Cync Full Color Deco Candle Base
GE Lighting, a Savant company
UA-SmartPlug-M028-US101
Uascent
Smart Plug
Leedarson
Shelly Plug US Gen4
Shelly
Sailsco Smart Plug
Saishigao
Cono Lamp
Umbra
WiZ A60 Filament
Signify
Govee Smart AI Sync Box
Shenzhen Qianyan Technology
MT-SL-ONOFF
Sunricher
M2D Bridge
innovation matters
WiZ A67.E27
Signify
Smart Wired Gateway Pro
Tuya
ML5
MiBoxer
Smart Light
Uascent
H61B8
Shenzhen Qianyan Technology
H61B9
Shenzhen Qianyan Technology
SMART WIFI MAT DUPLO 580 IP44 TW
LEDVANCE
Smart Plug
SONOFF
WiZ G25 Filament
Signify
Cup Lamp
Umbra
WiZ A.E27
Signify
00176655
Hama GmbH
SMART MAT PAR16 RGBW GU10
LEDVANCE
SmartCeilingFan
Eran