The Water Heater Mode cluster (0x009E) is a Matter cluster that Controls operating modes for water heaters.. It defines 2 commands and 2 attributes and is mandatory for 1 device type.
Water Heater Mode 0x009E
Controls operating modes for water heaters.
Spec History
This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.
Attributes 2
Commands 2
Features 1
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | SupportedModes | array | |
| 0x0001 | CurrentMode | int8u |
| Code | Name | Direction | Parameters |
|---|---|---|---|
| 0x00 |
ChangeToMode
This command is used to change device modes.
|
client→server |
NewMode: int8u |
| 0x01 |
ChangeToModeResponse
This command is sent by the device on receipt of the ChangeToMode command.
|
server→client |
Status: enum8, StatusText: char_string |
OnOff
(DEPONOFF)
bit 0
Dependency with the OnOff cluster
Device Types Using This Cluster
Device types in the Matter spec that reference this cluster
Devices Implementing This Cluster
0 devices in the survey implement this cluster
No devices in the survey implement this cluster yet.