The On/Off cluster (0x0006) is a Matter cluster that Controls the on/off state of a device. The most fundamental control cluster used by lights, switches, plugs, and many other devices.. It defines 6 commands and 5 attributes and is mandatory for 29 device types.
On/Off 0x0006
Controls the on/off state of a device. The most fundamental control cluster used by lights, switches, plugs, and many other devices.
Spec History
This cluster's ClusterRevision across the Matter releases it has shipped in. Click a version to inspect the cluster as it existed in that release.
Attributes 5
Commands 6
Features 3
| Code | Name | Type | Flags |
|---|---|---|---|
| 0x0000 | OnOff | boolean | |
| 0x4000 | GlobalSceneControl | boolean | Optional |
| 0x4001 | OnTime | int16u | Writable Optional |
| 0x4002 | OffWaitTime | int16u | Writable Optional |
| 0x4003 |
StartUpOnOff
max 2 · nullable
|
StartUpOnOffEnum | Writable Optional write: manage |
| Code | Name | Direction | Parameters |
|---|---|---|---|
| 0x00 |
Off
On receipt of this command, a device SHALL enter its ‘Off’ state. This state is device dependent, but it is recommended that it is used for power off or similar functions. On receipt of the Off command, the OnTime attribute SHALL be set to 0.
|
client→server | None |
| 0x01 |
On
Optional On receipt of this command, a device SHALL enter its ‘On’ state. This state is device dependent, but it is recommended that it is used for power on or similar functions. On receipt of the On command, if the value of the OnTime attribute is equal to 0, the device SHALL set the OffWaitTime attribute to 0.
|
client→server | None |
| 0x02 |
Toggle
Optional On receipt of this command, if a device is in its ‘Off’ state it SHALL enter its ‘On’ state. Otherwise, if it is in its ‘On’ state it SHALL enter its ‘Off’ state. On receipt of the Toggle command, if the value of the OnOff attribute is equal to FALSE and if the value of the OnTime attribute is equal to 0, the device SHALL set the OffWaitTime attribute to 0. If the value of the OnOff attribute is equal to TRUE, the OnTime attribute SHALL be set to 0.
|
client→server | None |
| 0x40 |
OffWithEffect
Optional The OffWithEffect command allows devices to be turned off using enhanced ways of fading.
|
client→server |
EffectIdentifier: EffectIdentifierEnum, EffectVariant: enum8 |
| 0x41 |
OnWithRecallGlobalScene
Optional This command allows the recall of the settings when the device was turned off.
|
client→server | None |
| 0x42 |
OnWithTimedOff
Optional This command allows devices to be turned on for a specific duration with a guarded off duration so that SHOULD the device be subsequently turned off, further OnWithTimedOff commands, received during this time, are prevented from turning the devices back on.
|
client→server |
OnOffControl: OnOffControlBitmap, OnTime: int16u, OffWaitTime: int16u |
Lighting
(LT)
bit 0
Behavior that supports lighting applications.
DeadFrontBehavior
(DF)
bit 1
Device has Dead Front behavior
OffOnly
(OFFONLY)
bit 2
Device supports the OffOnly Feature feature
Device Types Using This Cluster
Device types in the Matter spec that reference this cluster
📱
📺
📱
📺
📱
💡
🌉
📱
📱
💡
🔌
📱
📱
📱
💨
🌡
📱
📱
📱
🔘
💡
🔘
🔌
🔘
📱
📱
📱
🔊
📱
Air Purifier
Optional Server
Basic Video Player
Mandatory Server
Casting Video Client
Mandatory Client
Casting Video Player
Mandatory Server
Color Dimmer Switch
Mandatory Client
Color Temperature Light
Mandatory Server
Control Bridge
Mandatory Client
Cook Surface
Optional Server
Cooktop
Mandatory Server
Dimmable Light
Mandatory Server
Dimmable Plug-In Unit
Mandatory Server
Dimmer Switch
Mandatory Client
Dishwasher
Optional Server
Extended Color Light
Mandatory Server
Fan
Optional Server
Heating/Cooling Unit
Mandatory Server
Laundry Dryer
Optional Server
Laundry Washer
Optional Server
Mounted Dimmable Load Control
Mandatory Server
Mounted On/Off Control
Mandatory Server
On/Off Light
Mandatory Server
On/Off Light Switch
Mandatory Client
On/Off Plug-in Unit
Mandatory Server
On/Off Sensor
Mandatory Client
Pump
Mandatory Server
Pump Controller
Mandatory Client
Room Air Conditioner
Mandatory Server
Speaker
Mandatory Server
Video Remote Control
Mandatory Client
Devices Implementing This Cluster
377 devices in the survey implement this cluster
Touchscreen Switch S100
Aqara
matter-thread-light
Espressif Systems
Smart A19 LED Bulb
HONG KONG LAUNRAY INDUSTRY LIMITED
Philips P45.E27
Signify
Philips Ceiling
Signify
SmartCeilingFan
Eran
Shelly 1PM Mini Gen3
Shelly
Cync Indoor Light Strip 16ft
GE Lighting, a Savant company
Smart Indoor Plug - Single outlet
Amazon Basics
WiZ LED Strip
Signify
KAJPLATS E12 WS B38 CL 450lm
IKEA of Sweden
Smart Wi-Fi Outdoor Plug
Tapo
Smart Light
Tuya
Philips Candle
Signify
Philips GU10
Signify
Home Relay 16A Thread
WAGO
Philips A60 Filament
Signify
Govee Uplighter Floor Lamp
Shenzhen Qianyan Technology
Smart Switch MT1
ThirdReality
Tapo Smart Wi-Fi In-wall Outlet
Tapo
DEWENWILS 3 -Zone Transformer
DEWENWILS
Switch unit with inputs for external buttons MATTER
ELKO EP, s.r.o.
Mthread
MiBoxer
Smart RGBTW Bulb
Leedarson